Product description - KSD Series 301 temperature controller
Working principle :KSD301 series jump type temperature controller is a small bimetal plate type temperature controller with shell, belonging to the contact temperature sensing temperature relay class. The use of dish-shaped bimetallic sheet deformation under the action of temperature principle, through the mechanism, the contact rapid action, to connect or disconnect the electrical purpose, its operating temperature characteristics is fixed, do not need to adjust, reliable and simple action, no arc, long service life, less radio interference
Name of model:
Technical parameters:
Rated electrical performance: AC250V; Maximum working current 10/15A (resistance load)
Disconnect operation temperature: 45~250℃
Disconnect temperature tolerance: ±2℃±3℃±5℃
On-off action deviation: 10~25℃ (special requirements for negotiation); Manual reset Automatic reset The temperature is lower than 5 ℃
Service life: Not less than 100000 times under resistive load (not less than 6000 times for manual reset)
Normal electrical strength: AC50Hz2000V/1min, No breakdown flashover phenomenon
Normal insulation resistance: Greater than 100MΩ(DC500V Megohm meter )
Contact resistance: Not more than 50mΩ
Contact form :
1、Normally closed type: normally closed at room temperature, temperature rise contact disconnect
2 、Normally open type: normally open at room temperature, contact closed as the temperature rises
3 、Manual reset type: normally closed at room temperature, contact is disconnected when the temperature rises, and manual reset is connected when the temperature decreases
4 Manual reset normally open: normally open at room temperature, contact closed when the temperature rises, manual reset closed when the temperature decreases
Heat resistance :
Common type: maximum operating temperature ≤150℃, installation surface temperature ≤160℃
High temperature type: maximum operating temperature ≤250℃, installation surface temperature ≤280℃
Grounding mode: The metal enclosure of the thermostat is connected to the earth metal component.
Product application scope:
Bath bar, disinfection cupboard, steaming oven, microwave oven, dishwasher, electric cooking pot, water dispenser, electric heater, coffee pot, electric cake stall, electric oven, gas water heater, foot bath, air fryer; Or for motor, rectifier equipment, daily appliances and a variety of electric heating appliances
Instructions for ordering and Use:
Select the operating temperature and size of the thermostat according to the object used. Under normal circumstances, the products are supplied according to the common temperature. Users can put forward special requirements when needed, which can be solved through negotiation. Common temperature specifications (℃) : 15, 50, 55, 60, 65, 70, 80, 83, 85, 88, 90, 92, 95, 102, 110, 125, 135, 145, 150, 155, 160, 165, 170, 180, 185, 190, etc.
The user must, according to the characteristics of their own products, accurately determine the actual temperature to be controlled at the location where the thermostat is installed, determine the operating temperature of the thermostat through supporting tests, and then put forward the operating temperature value of the order. When using the thermostat, the metal cover should be as close to the installation site of the controlled device as possible. Do not let water and other substances infiltrate into the thermostat. Do not collapse or deform the cover during installation, so as to avoid temperature change or affect other performance.
Product description - KSD 302 series temperature controller
Working principle: KSD302 series jump type temperature controller is a small bimetal chip type temperature controller with shell bipolar disconnection, belonging to the contact temperature sensing type temperature relay class. The use of dish-shaped bimetallic sheet deformation under the action of temperature principle, through the mechanism, the contact rapid action, to connect or disconnect the electrical purpose, its operating temperature characteristics is fixed, do not need to adjust, reliable and simple action, no arc, long service life, less radio interference.
Name of model:
Technical parameters:
Rated electrical performance: AC250V; Maximum working current 15A, 16A, 20A (resistance load)
Disconnect operation temperature: 60~150℃
Disconnect temperature tolerance:±3℃±5℃
Reset operation temperature: manually reset
Enable life: not less than 10000 times under resistance load
Normal electrical strength: AC50Hz2000V/1min, no breakdown and flashover phenomenon
Normal insulation resistance: more than 100MΩ (DC500V megohm meter)
Contact resistance: not more than 50mΩ
Contact type: normally closed type: normally closed at room temperature, contact disconnected when the temperature rises, manually reset and connect when the temperature decreases
Heat resistance: maximum operating temperature ≤150℃, installation surface temperature ≤180℃
Ground square type: through the temperature controller metal shell and earth metal components connected.
Product application scope:
Can be used for temperature control of household appliances, such as: water storage water heater and kitchen treasure for overheating protection.
Instructions for ordering and Use:
Select the operating temperature and size of the thermostat according to the object used. Under normal circumstances, the products are supplied according to the common temperature. Users can put forward special requirements when needed, which can be solved through negotiation. Common temperature specifications (℃) : 60, 65, 70, 80, 83, 85, 88, 90, 92, 95, 102, 110, 125, 135, 145, 150, etc.
The user must, according to the characteristics of their own products, accurately determine the actual temperature to be controlled at the location where the thermostat is installed, determine the operating temperature of the thermostat through supporting tests, and then put forward the operating temperature value of the order. When using the thermostat, the metal cover should be as close to the installation site of the controlled device as possible. Do not let water and other substances infiltrate into the thermostat. Do not collapse or deform the cover during installation, so as to avoid temperature change or affect other performance.
Product description - KSD 304 series temperature controller
Working principle:KSD304 series jump type temperature controller is a small bimetal plate type temperature controller with shell bipolar disconnection, belonging to the contact temperature sensing type temperature relay class. The use of dish-shaped bimetallic sheet deformation under the action of temperature principle, through the mechanism, the contact rapid action, to connect or disconnect the electrical purpose, its operating temperature characteristics is fixed, do not need to adjust, reliable and simple action, no arc, long service life, less radio interference.
Name of model:
Technical parameters:
Rated electrical performance: AC250V; Maximum working current 45A (resistance load)
Disconnect operation temperature: 60~150℃
Disconnect temperature tolerance:±3℃±5℃
Reset operation temperature: manually reset
Enable life: not less than 10000 times under resistance load
Normal electrical strength: AC50Hz2000V/1min, no breakdown and flashover phenomenon
Normal insulation resistance: more than 100MΩ (DC500V megohm meter)
Contact resistance: not more than 50mΩ
Contact type: normally closed type: normally closed at room temperature, contact disconnected when the temperature rises, manually reset and connect when the temperature decreases
Heat resistance: maximum operating temperature ≤150℃, installation surface temperature ≤180℃
Ground square type: through the temperature controller metal shell and earth metal components connected.
Product application scope:
It can be used for temperature control of household appliances, such as fast water heater and electric heating faucet.
Instructions for ordering and Use:
Select the operating temperature and size of the thermostat according to the object used. Under normal circumstances, the products are supplied according to the common temperature. Users can put forward special requirements when needed, which can be solved through negotiation. Common temperature specifications (℃) : 60, 65, 70, 80, 83, 85, 88, 90, 92, 95, 102, 110, 125, 135, 145, 150, etc.
The user must, according to the characteristics of their own products, accurately determine the actual temperature to be controlled at the location where the thermostat is installed, determine the operating temperature of the thermostat through supporting tests, and then put forward the operating temperature value of the order. When using the thermostat, the metal cover should be as close to the installation site of the controlled device as possible. Do not let water and other substances infiltrate into the thermostat. Do not collapse or deform the cover during installation, so as to avoid temperature change or affect other performance.
Product description - KSD 305 series temperature controller
Working principle: KSD305 series jump type temperature controller is a small bimetal plate type temperature controller with shell, belongs to the contact temperature relay class. The use of dish-shaped bimetallic sheet deformation under the action of temperature principle, through the mechanism, the contact rapid action, to connect or disconnect the electrical purpose, its operating temperature characteristics is fixed, do not need to adjust, reliable and simple action, no arc, long service life, less radio interference.
Name of model:
Technical parameters:
Rated electrical performance: AC250V; Maximum working current 45A (resistance load)
Disconnect operation temperature: 45~150℃
Disconnect temperature tolerance:±2℃±3℃±5℃
On-off deviation: 10 ~ 25℃ (special requirements to be negotiated); Manual reset Automatic reset The temperature is lower than 5 ℃
Service life: no less than 30000 times under resistance load (no less than 10000 times for manual reset)
Normal electrical strength: AC50Hz2000V/1min, no breakdown and flashover phenomenon
Normal insulation resistance: more than 100MΩ (DC500V megohm meter)
Contact resistance: not more than 50mΩ
Contact type:
1· Normally closed type: normally closed at room temperature, temperature rise contact disconnect
2· Manual reset type: normally closed at room temperature, contact is disconnected when the temperature rises, and manual reset is connected when the temperature decreases
Heat resistance: maximum operating temperature ≤150℃, installation surface temperature ≤180℃
Ground square type: through the temperature controller metal shell and earth metal components connected.
Product application scope:
For high power household appliances temperature control, such as: fast electric water heater, commercial water dispenser; Or can be used for motor, rectifier equipment and a variety of electric heating appliances for temperature control and overheating protection.
Instructions for ordering and Use:
Select the operating temperature and size of the thermostat according to the object used. Under normal circumstances, the products are supplied according to the common temperature. Users can put forward special requirements when needed, which can be solved through negotiation. Common temperature specifications (℃) : 50, 55, 60, 65, 70, 80, 83, 85, 88, 90, 92, 95, 102, 110, 125, 135, 145, 150, etc.
The user must, according to the characteristics of their own products, accurately determine the actual temperature to be controlled at the location where the thermostat is installed, determine the operating temperature of the thermostat through supporting tests, and then put forward the operating temperature value of the order. When using the thermostat, the metal cover should be as close to the installation site of the controlled device as possible. Do not let water and other substances infiltrate into the thermostat. Do not collapse or deform the cover during installation, so as to avoid temperature change or affect other performance.
Product description - KSD 308 series temperature controller
Working principle: KSD308 series jump type temperature controller is a small bimetal chip type temperature controller with a shell with four poles disconnected, belonging to the contact temperature relay class. The use of dish-shaped bimetallic sheet deformation under the action of temperature principle, through the mechanism, the contact rapid action, to connect or disconnect the electrical purpose, its operating temperature characteristics is fixed, do not need to adjust, reliable and simple action, no arc, long service life, less radio interference.
Name of model:
Technical parameters:
Rated electrical performance: AC400V; Maximum working current 37, 45, 63A3N (resistance load)
Disconnect operation temperature: 60~150℃
Disconnect temperature tolerance:±3℃±5℃
Reset operation temperature: manually reset
Enable life: not less than 10000 times under resistance load
Normal electrical strength: AC50Hz2000V/1min, no breakdown and flashover phenomenon
Normal insulation resistance: more than 100MΩ (DC500V megohm meter)
Contact resistance: not more than 50mΩ
Contact type: normally closed type: normally closed at room temperature, contact disconnected when the temperature rises, manually reset and connect when the temperature decreases
Heat resistance: maximum operating temperature ≤150℃, installation surface temperature ≤180℃
Ground square type: through the temperature controller metal shell and earth metal components connected.
Product application scope:
Can be used for temperature control of household appliances, such as: three-phase fast water heater for overheating protection.
Instructions for ordering and Use:
Select the operating temperature and size of the thermostat according to the object used. Under normal circumstances, the products are supplied according to the common temperature. Users can put forward special requirements when needed, which can be solved through negotiation. Common temperature specifications (℃) : 60, 65, 70, 80, 83, 85, 88, 90, 92, 95, 102, 110, 125, 135, 145, 150, etc.
The user must, according to the characteristics of their own products, accurately determine the actual temperature to be controlled at the location where the thermostat is installed, determine the operating temperature of the thermostat through supporting tests, and then put forward the operating temperature value of the order. When using the thermostat, the metal cover should be as close to the installation site of the controlled device as possible. Do not let water and other substances infiltrate into the thermostat. Do not collapse or deform the cover during installation, so as to avoid temperature change or affect other performance.
Copyright © Suzhou Junheng Electric Appliance Co., LtdAdd:He Hua Village, Shengze Town, Wujiang District, Suzhou City Record:蘇ICP備2020061824號(hào)-2